Omicron logo | Omicron Sensing Logo
Product Range
PRESSURE INSTRUMENTS
TEMPERATURE INSTRUMENTS
LEVEL INSTRUMENTS
FLOW INSTRUMENTS
HUMIDITY INSTRUMENTS
CLEANROOM INSTRUMENT
HVAC / BMS SENSORS
AIR QUALITY SENSOR
VOC8-Indoor Air Quality Transmitters
CMW-Wall Mounted Carbon Monoxide Transmitter
CMW-LCD - Wall Mounted Carbon Monoxide Transmitter With Display
CDW-Wall Mounted Carbon Dioxide Transmitter
CDW-LCD-Wall Mounted Carbon Dioxide Transmitter with Display
CDM-Duct Mounted Carbon Dioxide Transmitter
IAQ-1000-Indoor Air Quality Transmitter
IAQ-1002-Indoor Air Quality Transmitter
SGT35-Smart Gas Transmitter For Toxic / Combustible Gases
SGT45-VOC Gas Transmitter
WATER QUALITY SENSOR
VAV BOXES
BTU METER
VALVES
INDICATORS & CONTROLLERS
DATALOGGER
PORTABLE INSTRUMENTS
ACCESSORIES
ONLINE CATALOGUE
CATALOGUE REQUEST
 

IAQ-1000 : Indoor Air Quality Transmitter

Parameter : O2
Mounting : Wall
Range : 0 to 25%
Display : Optional
Accuracy : ± 2% of F.S
Output : 4 - 20mA
: 0 - 10VDC
 
Special Features
High performance NDIR sensors and circuits, ensure accurate measurement and temperature compensation
Good long term stability and reliability
15 Years Sensor Life
Fast response
Digital technology applied, multiple output optional, over voltage and reverse polarity protection, high reliability and interference capability
Fast Response
High protection rate up to IP65
 
Application
Omicron carbon dioxide transmitters are designed for environment monitoring and controlling in industrial and commercial buildings
Air monitoring of supply, exhaust and return air
Air monitoring in critical environment such as outside air
Other applications of combustion measurement
 
Specifications
IAQ-1000:
Sensor : Dual Beam NDIR
Range : 0-3,000 ppm
Output : -RS485 Modbus and Analog Output (0-5V , 0-10V,4-20mA)
Accuracy   ±70 ppm or ±5% of reading
     
Relative Humidity:  
Sensor : capacitance polymer,
Range : 0~100% non condensing
Output : (4-20mA, 0-5V or 0-10V option by jumper),RS 485 exist
Accuracy : 5% RH (25°C, 20~80% RH)
Hysteresis : < ±1% RH
Response time : < 10s (25°C, in slow air)
Drift : < ±0.5% RH / year
     
Temperature:  
Sensor : 10K internal
Range : -40~150°C(-60~340°F)/transmitter
Output : (4-20mA, 0-5V or 0-10V option by jumper),RS 485 exist
Accuracy : < ±0.5°C @ 25°C
     
General  
Power : 12 to 24V AC or DC, ±10%
Current Output Load
for 4-20mA
: < 500
Display : LCD screen for wall / outdoor mount and duct mount
Display Resolution : 0.1°C, 0.1% RH
Temperature Limit : -40~150°C, 0~95% RH(Non condensing)
Plastic Housing : Flammability rating UL 94V0 file E194560
     
     
 
 
 
Copyrights @ Omicron Sensing Inc. All rights reserved.