Product Range |
|
|
PRESSURE INSTRUMENTS |
|
|
|
TEMPERATURE INSTRUMENTS |
|
|
|
LEVEL INSTRUMENTS |
|
|
|
|
FLOW INSTRUMENTS |
|
|
Flow Switches |
|
Flow Gauges |
|
Flow Transmitter |
|
F8100 - Vortex Flow Meter |
|
F8200 - P & T Compensated Vortex Flow Meter |
|
F6700 - E/M Flow Transmitter |
|
F6700 - Insertion Type |
|
APR2000 - DP Flow Transmitter |
|
|
S280W : Ultrasonic Flow Transmitter |
|
TF100-Thermal Mass Flowmeter |
|
F4900 - Liquid Turbine Flow Meter |
|
F5100 - Coriolis Mass Flowmeter |
|
MTF - Variable Flow Meter |
|
F-244 : Flow Indicator Totaliser |
|
S301 : Economical Ultrasonic Flowmeter |
|
S300H : Ultrasonic Flowmeter |
|
PWF : Flow Transmitter |
|
|
HUMIDITY INSTRUMENTS |
|
|
|
CLEANROOM INSTRUMENT |
|
|
|
HVAC / BMS SENSORS |
|
|
|
AIR QUALITY SENSOR |
|
|
|
WATER QUALITY SENSOR |
|
|
|
VAV BOXES |
|
|
|
BTU METER |
|
|
|
VALVES |
|
|
|
INDICATORS & CONTROLLERS |
|
|
|
DATALOGGER |
|
|
|
PORTABLE INSTRUMENTS |
|
|
|
ACCESSORIES |
|
|
|
ONLINE CATALOGUE |
|
|
|
CATALOGUE REQUEST |
|
|
|
|
F-244 : Flow Indicator Totaliser |
|
|
Special Features |
|
|
Indication through LED |
|
Input selectable as linear / square root. |
|
Normal / Batch mode for operation |
|
Averaging of inputs for turbulent flow. |
|
Programmable low flow cut-off. |
|
Software calibration. |
|
|
Application |
Series F-244 is micro-controller based flow indicator totaliser designed for various industrial applications.These can be used for indication & totalisation of flow. The input can be processed linearly or square rooted.The built-in battery back-up is provided for the memory to avoid loss of data in case of power failure.The micro-controller based design provides full flexibility for flow metering applications. |
|
Specifications |
|
|
Operating Modes |
: |
Normal / Batch |
|
Input |
: |
Linear / Square Rooted |
|
|
|
1) Current ( 4-20 mA)
2) Voltage (1-5 V / 0-5 V)
3) Frequency (0-10 Khz) |
|
Display |
: |
4 digit, 0.5” Red LED for Flow Rate & 8 digit, 0.3” Red LED for Totalised Flow |
|
Range |
: |
Programmable (0 to 9999) |
|
Accuracy |
: |
Better than + 0.25% of F. S. |
|
Open Sensor Indication |
: |
Provided |
|
Power Supply |
: |
1) 24 V DC, External |
|
|
|
2) 90 - 250 V AC, 50 Hz |
|
Power Consumption |
: |
Less than 10 VA |
|
Temperature Drift |
: |
< 0.01% of F. S. per °C change |
|
Response Time |
: |
< 100 mSec |
|
Isolation |
: |
1.4 KV between Input, Output & Power Supply |
|
Enclosure |
: |
1) DIN Std |
|
|
|
2) Weather-proof, IP-65 |
|
|
|
3) Flame-proof, IP-65, IIA, IIB CMRI Certified |
|
Dimensions |
: |
96 (H) x 96 (W) X 250 (D) in mm approx. for DIN std. enclosure |
|
Mounting |
: |
Flush of the Panel for DIN std. enclosure & wall mount for WP& FLP enclosure |
|
Weight |
: |
2 kg (Approx.) |
|
Operating Conditions |
: |
Temperature 0 to 55 0C / Humidity 5 to 95% non condensing |
|
|
|
|
|
|
|
|